TM 9-4933-223-13&P
3-19. SWITCHBOX AND MOUNTING BRACKET (WITHOUT TOGGLE SWITCH)--MAINTENANCE INSTRUCTIONS (cont)
REASSEMBLY/INSTALLATION
NOTE
For
clarity,
wires
not
mentioned in text are not
shown.
2
BLUE WIRE NO. 4 (4), BLUE WIRE
NO. 5 (5), BLUE WIRE NO. 6 (6), AND
GREEN WIRE NO. 11 (7). Push into
switchbox (8).
3
CONNECTOR (9). Install in switchbox
(8).
1
MOUNTING BRACKET (1). Install two
flat washers (2) and two hex head
capscrews (3).
4
MICROSWITCH (10). Install in hole
(11) in back of switchbox (8) and
through hole (12) in mounting
bracket (1).
NOTE
Adjust microswitch so that
plunger protrudes enough so
when door bolt is closed the
plunger is depressed, and
when door bolt is open the
plunger is released.
For
further instructions, refer to
adjustment of microswitch, p
5
WASHER (13) AND HEX , NUT (14). Install.
3-184