120/208V CABLE ASSEMBLY--MAINTENANCE INSTRUCTIONS
REMOVAL - continued - TM-9-4933-223-13-P0337

TM-9-4933-223-13-P Shelter Shop Set Aviation Intermediate Maintenance (DIV) Armament Repair Air Mobile Shelter-Mounted 4933-01-082-1663 Manual
Page Navigation
  320    321    322    323    324  325  326    327    328    329    330  
TM 9-4933-223-13&P
3-39. 120/208V CABLE ASSEMBLY--MAINTENANCE INSTRUCXTIONS (cont.)
REMOVAL (cont.)
1
ELECTRICAL  PLUG  CONNECTOR  (FEMALE)  (1)  AND
ELECTRICAL PLUG CONNECTOR (MALE) (2). Check for bent
or broken parts.
2 CABLE (3).
a.
Check for worn, cracked, or cut insulation.
b.
Check for cut or broken wires.
3 TWO GLANDS (4). Check for deformed or deteriorated condition.
REMOVAL
4
TWO GRIPS (5).
Check for broken
WARNING
parts.
De-energize shop set by placing
circuit
breaker
on
power
5
TWO DUST COVERS (6). Check for
distribution panel connected to
bent or broken parts.
power source in OFF position
and then disconnect 120/208V
6
BAND (7). Check to ensure it is not
cable assembly from shelter
missing and is readable
.