TM 9-4933-223-13&P
4 CABLE (4).
a.
Repair, if possible, damaged insulation or wires by shortening
slightly.
b.
Replace with a 100-ft (30.48-m) long piece of cable (fig. 22,
5 TWO GLANDS (5). Replace if deformed or deteriorated.
6 TWO GRIPS (6). Replace if broken.
7 TWO DUST COVERS (7). Replace if bent or broken.
8 BAND (8).
a.
Clearly mark any hard to read parts with black letters 0.31-in.
(0.79-cm) high, using marking ink (item 17, app D), to read as
follows:
CABLE ASSEMBLY
PART NO. 72289-100
REASSEMBLY
NOTE
1
CABLE (1).
The following procedures pertain to
a.
Cut both ends square.
assembly of the electrical plug
b.
Remove outer jacket (2) to
connector
(male).
4.25 in. (10.80 cm) from each
end.
3-285