Figure 1. Unsecure Eyewash Station.
POSITIONING CASE SETS FOR OPERATIONAL MODE

Operator Manual \(Rpstl\) For Pneudraulic Shop P/N Sc4920-99-Clc64 And Part No 1036258
Page Navigation
  60    61    62    63    64  65  66    67    68    69    70  
img
TM 1-4920-433-13&P
0013 00
- CONTINUED
8.
Attach eyewash station wall bracket (Figure 1, Item 5) by installing two bolts (Figure 1, Item 8), two lock
washers (Figure 1, Item 7), and two lat washers (Figure 1, Item 6).
Torque bolts (Figure 1, Item 8) 160-190 in. lbs.
9.
Figure 2.
Position Eyewash Station.
10. Mount eyewash station (Figure 2, Item 1) onto wall bracket (Figure 2, Item 2).
11. Fill eyewash station with eye and face wash fountain solution IAW Eyewash Station Owner s Manual.
END OF WORK PACKAGE