Figure 5. Disconnecting PDB from Generator.
REMOVING LIGHTING

Maintenance Manual For Engine Shop Part No. 1035258 And Part No. Sc4920-99-Cla60
Page Navigation
  99    100    101    102    103  104  105    106    107    108    109  
img
0026 00
TM 1-4920-436-13&P
REMOVING EXTERNAL GROUND ROD
NOTE
Shelter is grounded through externally connected power supply.
Figure 6.
Removing External Grounding Rod.
1.
On power entry panel (Figure 6, Item 1) remove nut (Figure 6, Item 2), lock washer (Figure 6, Item 3), and lat
washer (Figure 6, Item 4) from ground stud (Figure 6, Item 7).
2.
Disconnect ground cable lug (Figure 6, Item 5) from ground stud (Figure 6, Item 7).
3.
Replace lat washer (Figure 6, Item 4), lock washer (Figure 6, Item 3), and nut on ground stud (Figure 6, Item
7).
4.
Remove grounding rod (Figure 6, Item 6) from ground.
5.
Store grounding rod assembly in secure storage location.
END OF WORK PACKAGE