TM 1-4920-436-13&P
0028 00
LOWERING SHELTER ROOF
WARNING
When all equipment and material are stored in stationary side of shelter, limited loor space
presents a safety hazard to personnel. This is most critical during raising and lowering
of roof panel. Personnel inside shelter could become trapped between roof panel and
equipment bolted to loor. Failure to observe warning could result in SERIOUS INJURY to
personnel.
Four personnel are required to perform all of the following procedures. Failure to observe
warning could result in SERIOUS INJURY to personnel.
CAUTION
When swinging end wall closed, D-rings on ECU panel should be pressed lat against panel to
prevent damage to hinged roof.
Figure 3.
Lowering Shelter Roof.
1.
Two personnel inside shelter, using support strut assemblies (Figure 3, Item 2), will lower roof panel (Figure
3, Item 1) until two personnel outside can reach and hold weight of roof panel (Figure 3, Item 1).
0028 00-3