TM 1-4920-436-13&P
0055 00
REMOVAL CONTINUED
1.
On power entry panel (Figure 3, Item 1) remove nut (Figure 3, Item 2), lock washer (Figure 3, Item 3), and lat
washer (Figure 3, Item 4) from ground stud (Figure 3, Item 7).
2.
Disconnect ground cable lug (Figure 3, Item 5) from ground stud (Figure 3, Item 7).
3.
Replace lat washer (Figure 3, Item 4), lock washer (Figure 3, Item 3), and nut (Figure 3, Item 2) on ground
stud (Figure 3, Item 7).
INSTALLATION
1.
Remove nut (Figure 3, Item 2), lock washer (Figure 3, Item 3), and lat washer (Figure 3, Item 4) from ground
stud (Figure 3, Item 7) on power entry panel (Figure 3, Item 1).
2.
Connect ground cable lug (Figure 3, Item 5) to ground stud (Figure 3, Item 7).
3.
Secure with lat washer (Figure 3, Item 4), lock washer (Figure 3, Item 3), and nut (Figure 3, Item 2).
4.
Ensure all connections are secure.
END OF WORK PACKAGE
0055 00-3/4 blank