Figure 9. Aligning Bolt Holes of ECU (B) with ECU Fold-down Panel.
POSITIONING CASE SETS FOR OPERATIONAL MODE

Aviation Maintenance Manual For Power Train Shop P/N 1036459 And P/N Sc492097Cla65
Page Navigation
  56    57    58    59    60  61  62    63    64    65    66  
img
0011 00
TM 1-4920-438-13&P
CONNECTING POWER TO ECUS
NOTE
There are several ECU conigurations compatible for this shop set. Refer to the applicable ECU
Owner s Manual for operating, grounding, and maintenance instructions.
Figure 11.
Connecting Power to ECU s.
1.
Inspect installation of ECU (A) (Figure 11, Item 1) and power cable (Figure 11, Item 3).
2.
Position MODE switch (Figure 11, Item 2) to OFF position.
3.
Remove protective dust cap (Figure 11, Item 7) from power input receptacle (Figure 11, Item 6).
4.
Push end of connector (Figure 11, Item 5) into power input receptacle (Figure 11, Item 6) until seated.
5.
Screw connector lock ring (Figure 11, Item 4) on power input receptacle (Figure 11, Item 6).
6.
Repeat Steps 1 through 5 for ECU (B).
END OF WORK PACKAGE