POSITIONING EYEWASH STATION FOR TRANSPORT MODE
POSITIONING EYEWASH STATION ASSEMBLY BRACKET AND HARDWARE FOR TRANSPORT MODE

Operator Manual For Tool Crib Shop Part No. 1036058 & Part No. Sc4920-99-Cla69
Page Navigation
  84    85    86    87    88  89  90    91    92    93    94  
img
0023 00
TM 1-4920-441-13&P
POSITIONING EYEWASH STATION ASSEMBLY BRACKET AND HARDWARE FOR TRANSPORT MODE
Figure 1.
Secure Eyewash Station Assembly Bracket and Hardware.
1.
Drain eye and face wash fountain solution from eyewash station (Figure 1, Item 6) IAW Sperian Fendall Pure
Flow 1000 Eyewash Station Owner s Manual.
2.
Remove eyewash station (Figure 1, Item 6) from eyewash station wall bracket (Figure 1, Item 4) and set
aside.
3.
Remove two bolts (Figure 1, Item 1), two lock washers (Figure 1, Item 2), two lat washers (Figure 1, Item 3),
and wall bracket (Figure 1, Item 4).