TM 10-5411-236-13&P
0034 00
REPLACE
1. Remove both modules per WP 0007 00.
2. Remove bolts (1) using 3/4-inch socket wrench.
3. Remove the floor adapter plate (2) from the FPU-8 using MHE with sling or strap.
4. Position replacement floor adapter plate using MHE and sling or strap inside FPU-8.
5. Apply locktite 262 red to the bolt threads.
6. Insert twelve bolts finger tight only.
7. Tighten using 3/4-inch socket.
8. Replace both modules per WP 0007 00.
1
1
2
1
REPAIR
1. Floor adapter plate (1) may have to be removed from the FPU-8 in order to facilitate certain repairs.
2. Correct operator reported problems with floor adapter plate as required.
3. Cracks may occur in corners and around mounting holes and bracket welds.
0034 00-2