Item
No.
3
Table 3-2. Organizational Preventive Maintenance Checks and Services
W - Weekly
M -
TM 5-3610-256-14
(Continued)
Monthly
Interval
W
M
Item to be Inspected
Procedure
CHECK AMMONIA ABSORBER (CONTINUED)
4. Place new absorber container in position and
connect tubing.
5. Remove and stow safety goggles.
6. Dispose of old absorber container.
TEST AMMONIA SUPPLY.
Ammonia vapor may cause injury or
death. Do not breathe vapor. Ensure
adequate ventilation prior to servicing
or operating Reproduction Set.
Ammonia may cause eye injury or blind-
ness. Wear eye protection before ser-
vicing ammonia system.
Ammonia may cause skin burns or
irritation. Do not let ammonia con-
tact skin or clothing.
3-17