TM 10-5411-236-13&P
0017 00
Table 1. Cleaning
SALT/MUD/DIRT
SURFACE
OIL/GREASE
RUST/CORROSION
DEBRIS
Corrosion Removal
Exterior and Interior
Detergent, Water,
Soapy Water, Brush,
Compound and Wire Brush,
Dry Rag, Coat with Lube Oil
Walls (All)
Rags
Rags
or Spot Paint
EPC Cover, ASLMS
Detergent, Water,
Soapy Water, Brush
N/A
Module Cover, Nets
Rags
Seals and Gaskets
Damp and Dry Rags
Damp and Dry Rags
N/A
Corrosion Removal
Detergent, Water,
Soapy Water, Brush,
Compound and Wire Brush,
Rags (Remove,
Rags (Remove, clean
Module Cradles, FPU
Dry Rags, Coat with Lube
clean, and replace
Floor
and replace rubber pad
Oil or Spot Paint (Remove,
rubber pad into
into footing)
clean, and replace rubber
footing)
pad into footing)
Container Door
Brush, Rag and
Corrosion Removal
Hinges, Module
lubricate as needed to
Compound and Wire Brush,
N/A
Glides, and Glide Out
ensure rollers travel
Dry Rags and Lubricate as
Tracks/Rollers
freely
needed
See the individuals
See the individuals
See the individuals
operator's manual
operator's manual for
operator's manual for each
other Accessories
for each piece of
each piece of
piece of equipment
equipment
equipment
Table 2. Lubrication
FLUID or
EXPECTED
USAGE
CAPACITIES
INTERVAL
LUBRICANT
TEMPERATURES
General
Monthly or as
Purpose
required if under
Door Hinges
As Required
All Temperatures
Lubricating Oil
adverse
10W
conditions
Molykote
Monthly or as
Multipurpose
required if under
Door Cam Locks
Synthetic
As Required
All Temperatures
adverse
Grease P/N
conditions
26040124
Molykote
Monthly or as
Multipurpose
required if under
Door Seals
Synthetic
As Required
All Temperatures
adverse
Grease P/N
conditions
26040124
Molykote
Monthly or as
Multipurpose
Door Lock Shaft
required if under
Synthetic
As Required
All Temperatures
adverse
Pivot Bearing
Grease P/N
conditions
26040124
General
Monthly or as
Purpose
required if under
Folding Steps
As Required
All Temperatures
Lubricating Oil
adverse
10W
conditions
0017 00-2