Figure 3. Loops and Clamps Installation.
UNUSUAL ENVIRONMENT/WEATHER

Operator Manual \(Rpstl\) For Pneudraulic Shop P/N Sc4920-99-Clc64 And Part No 1036258
Page Navigation
  116    117    118    119    120  121  122    123    124    125    126  
img
0031 00
TM 1-4920-433-13&P
UNUSUAL ENVIRONMENT/WEATHER CONTINUED
OPERATION IN HIGH WINDS CONTINUED
NOTE
A minimum of a quarter turn is required to achieve maximum holding power.
Figure 4.
Securing Loops and Clamps.
5.
Insert driving rod through loop and pull up sharply to ensure anchor is set into ground.
NOTE
When moving shelter, disassemble storm coniguration kit and cut cable as close to ground as
possible. Discard cable components. Retain the two tie-down rings and store in shelter BII box.
Figure 5.
Attaching Loops and Clamps.
6.
Remove clamp, loop cable at six places (two with tie-down rings) as shown.
7.
Replace clamp and tighten clamp nuts.