WARNING
Load balancer is a spring powered mechanism. PERSONAL INJURY OR DEATH may result if
two quick release pins are not installed in stop plates.
Figure 5.
Load Balancer Slide Stops, Lower Position.
6.
Remove lockout pins (Figure 5, Item 4) from upper position on both load balancers (Figure 5, Item 3).
7.
Close slide stops (Figure 5, Item 1) against support cables (Figure 5, Item 2) on both load balancers.
8.
Install lockout pins in lower position on both load balancers.