Figure 1. Unsecure Eyewash Station.
POSITIONING THROATLESS SHEARING MACHINE FOR OPERATIONAL MODE

Field Maintenance Manual For Sheet Metal Shop Part No. 1035658 And Part No. Sc4920-99-A68
Page Navigation
  60    61    62    63    64  65  66    67    68    69    70  
img
TM 1-4920-435-13&P
0012 00
POSITIONING EYEWASH STATION FOR OPERATIONAL MODE - CONTINUED
2.
Store cargo straps (Figure 1, Item 3) in secure storage location.
3.
Remove two bolts (Figure 1, Item 8), two lock washers (Figure 1, Item 7), and two lat washers (Figure 1, Item
6) from shelter BII box.
4.
Remove eyewash station wall bracket (Figure 1, Item 5) from inside eyewash station.
5.
On expanded wall, align insert holes (Figure 1, Item 4) with eyewash station wall bracket (Figure 1, Item 5).
6.
Inspect two bolts (Figure 1, Item 8) for thread damage or rounded heads.
7.
Replace bolts (Figure 1, Item 8) if damage is detected.
8.
Attach eyewash station wall bracket (Figure 1, Item 5) by installing two bolts (Figure 1, Item 8), two lock
washers (Figure 1, Item 7), and two lat washers (Figure 1, Item 6).
Torque bolts (Figure 1, Item 8) 160-190 in. lbs.
9.
Figure 2.
Position Eyewash Station.
10. Mount eyewash station (Figure 2, Item 1) onto wall bracket (Figure 2, Item 2).
11. Fill eyewash station with eye and face wash fountain solution IAW Eyewash Station Owner s Manual.
END OF WORK PACKAGE
0012 00-3/4 blank