Figure 6. Electrical Plug Connector.
MAINTENANCE INSTRUCTIONS FOR CIRCUIT BREAKERS

Field Maintenance Manual For Sheet Metal Shop Part No. 1035658 And Part No. Sc4920-99-A68
Page Navigation
  230    231    232    233    234  235  236    237    238    239    240  
img
0059 00
TM 1-4920-435-13&P
INSTALLATION CONTINUED
ELECTRICAL PLUG CONNECTOR CONTINUED
7.
Crimp ive pins (Figure 6, Item 1) onto ive wires (Figure 6, Item 2).
8.
Insert wires (Figure 6, Item 2) into rear of connector (Figure 6, Item 12) in the following order:
a.
Insert black wire into the A cup.
b.
Insert red wire into the B cup.
c.
Insert orange wire into the C cup.
d.
Insert white wire into the D cup.
e.
Insert green wire into the E cup.
9.
Ensure wires (Figure 6, Item 2) are properly secured into rear of connector (Figure 6, Item 12).
10. Tighten connector end (Figure 6, Item 12) into threaded sleeve (Figure 6, Item 9).
11. Tighten back shell (Figure 6, Item 8) onto threaded sleeve (Figure 6, Item 9).
12. Secure electrical plug connector (Figure 6, Item 13) to power cable (Figure 6, Item 4) by installing two cable
clamps (Figure 6, Item 6), two lat head screws (Figure 6, Item 5) and two threaded sleeve nuts (Figure 6,
Item 7).
13. Perform operational checks.
END OF WORK PACKAGE