POSITIONING ROOF AND HINGED END WALLS CONTINUED
Figure 15.
Shelter Leveling.
8.
Rotate hinged jack handles (Figure 15, Item 2) counterclockwise simultaneously to raise both hinged jack
assemblies (Figure 15, Item 6) until positioning marks (Figure 15, Item 1) on hinged end walls and hinged
sidewall are in alignment.
9.
Use support strut assemblies (Figure 15, Item 3) to lower hinged roof to rest on hinged end walls and sidewall.
10. Remove pins (Figure 15, Item 5) from support strut assemblies (Figure 15, Item 3).
11. Retract support assemblies (Figure 15, Item 3) and secure in support brackets (Figure 15, Item 4) on hinged
roof with pins.
12. Adjust hinged jack assemblies (Figure 15, Item 6) to ensure positioning marks (Figure 15, Item 1) on hinged
roof and hinged sidewall are properly aligned.
0005 00-15