TM 1-4920-436-13&P
0043 00
REMOVAL
WARNING
HIGH VOLTAGE exists in electrical system of shop. All electrical inspections, repairs, or
replacements will be performed with power OFF and only by a qualiied electrician. Serious
shock hazards exist which could result in INJURY OR EVEN DEATH to personnel.
Figure 2.
Replace BNC Connector Assembly.
1.
Move main circuit breaker to OFF position.
2.
Remove four screws (Figure 2, Item 3) attaching power entry panel cover (Figure 2, Item 1) to power entry
panel which is located below circuit breaker panel.
3.
Remove power entry panel cover (Figure 2, Item 1) from power entry panel.
4.
Remove damaged BNC connector (Figure 2, Item 2) attached to power entry panel by twisting BNC cable
connector (Figure 2, Item 4) counter clockwise.
5.
Remove damaged BNC connector (Figure 2, Item 2) attached to power entry panel cover (Figure 2, Item 1)
by twisting BNC cable connector (Figure 2, Item 4) counter clock- wise.
6.
Remove damaged cable (Figure 2, Item 2).
0043 00-3