POSITIONING ECUS FOR TRANSPORT MODE
POSITIONING ECU (B) FOR TRANSPORT MODE - CONTINUED

Aviation Maintenance Manual For Power Train Shop P/N 1036459 And P/N Sc492097Cla65
Page Navigation
  98    99    100    101    102  103  104    105    106    107    108  
img
. . . . . .
0029 00
TM 1-4920-438-13&P
DISCONNECTING POWER FROM ECUS - CONTINUED
1.
Set MODE switch (Figure 1, Item 2) on ECU (B) (Figure 1, Item 1) to OFF position.
2.
Unscrew connector lock ring (Figure 1, Item 4) from power input receptacle (Figure 1, Item 6).
3.
Pull end of connector (Figure 1, Item 5) from power input receptacle (Figure 1, Item 6).
4.
Store power cable (Figure 1, Item 3) in secure storage location.
5.
Install protective dust cap (Figure 1, Item 7) on power input receptacle (Figure 1, Item 6).
6.
Repeat Steps 1 through 5 for ECU (A).
POSITIONING ECU (B) FOR TRANSPORT MODE
1.
Remove four setscrews from ECU (B) transport location loor inserts and store in shelter BII box (WP 0002 00,
Figure 2, Item 8 or WP 0002 00, Figure 3, Item 8).
2.
Remove two cargo straps from secure storage location and three ring bolts from shelter BII box (WP 0002 00,
Figure 2, Item 8 or WP 0002 00, Figure 3, Item 8).
3.
Install three ring bolts into loor inserts at transport location.
Figure 2.
Removing ECU (B) Hardware from ECU Fold-down Panel.
4.
Remove mounting hardware securing ECU (B) (Figure 2, Item 1) to ECU fold-down panel (Figure 2, Item 2).
5.
Store hardware in shelter BII box (WP 0002 00, Figure 2, Item 8 or WP 0002 00, Figure 3, Item 8).
0029 00-2