• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Figure 4. Box Connector.
MAINTENANCE INSTRUCTIONS FOR ECU POWER CABLE ASSEMBLY - Continued

Aviation Maintenance Manual For Power Train Shop P/N 1036459 And P/N Sc492097Cla65
Page Navigation
  204    205    206    207    208  209  210    211    212    213    214  
img
TM 1-4920-438-13&P
0054 00
REMOVAL
BOX CONNECTOR FOR ECU POWER CABLE
Figure 5.
Box Connector Replacement.
WARNING
HIGH VOLTAGE exists in electrical system of shop. All electrical inspections, repairs, or
replacements will be performed with power OFF and only by a qualiied electrician. Serious
shock hazards exist which could result in INJURY OR EVEN DEATH to personnel.
NOTE
This procedure covers obsolete NQOB circuit breaker panel and new NQOD circuit breaker
panel. These units are distinguishable by nameplates attached to panel boards.
1.
Tag and disconnect shelter electrical power.
2.
Set all circuit breaker switches to OFF position.
3.
Open circuit breaker panel door
0054 00-7