• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
MAINTENANCE INSTRUCTIONS FOR ECU POWER CABLE ASSEMBLY - Continued
ELECTRICAL PLUG CONNECTOR CONTINUED

Aviation Maintenance Manual For Power Train Shop P/N 1036459 And P/N Sc492097Cla65
Page Navigation
  206    207    208    209    210  211  212    213    214    215    216  
img
TM 1-4920-438-13&P
0054 00
INSPECTION OF INSTALLED ITEMS
ELECTRICAL PLUG CONNECTOR
NOTE
If ECU NSN 4120-01-523-4472 is being used, it may be necessary to change existing electrical
plug connector on end of ECU cables to electrical plug connector (NSN 5935-01-413-4953) to
ensure ECU power cable is compatible with ECU.
Figure 6.
Electrical Plug Connector.
1.
Inspect electrical plug connector (Figure 6, Item 13) for damage that prevents safe operation.
2.
Replace electrical plug connector (Figure 6, Item 13) if damage exists.
REMOVAL
ELECTRICAL PLUG CONNECTOR
Cut through power cable (Figure 6, Item 4) behind back shell (Figure 6, Item 8), removing electrical plug connec-
tor (Figure 6, Item 13).
INSTALLATION
ELECTRICAL PLUG CONNECTOR
1.
Strip 1.5 inch of outer insulation from power cable (Figure 6, Item 4).
2.
Strip .5 inch of outer insulation (Figure 6, Item 3) from ive wires (Figure 6, Item 2) contained within power
cable (Figure 6, Item 4).
3.
Install back shell (Figure 6, Item 8) onto power cable (Figure 6, Item 4).
4.
Install threaded sleeve (Figure 6, Item 9) into back shell (Figure 6, Item 8).
5.
Place locking washer (Figure 6, Item 10) inside of threaded sleeve (Figure 6, Item 9).
6.
Place threaded locking ring (Figure 6, Item 11) onto connector end (Figure 6, Item 12).
0054 00-9