Figure 9. Aligning Bolt Holes of ECU (B) with ECU Fold-down Panel.
POSITIONING SHOP ECU S FOR OPERATIONAL MODE - Continued

Maintenance Manual For Production/ Quality Control Shop Part No. 1036659 And Part No. Sc4920-99-Cla66
Page Navigation
  57    58    59    60    61  62  63    64    65    66    67  
img
. . . .
TM 1-4920-440-13&P
0011 00
POSITIONING ECU (B) FOR OPERATIONAL MODE - CONTINUED
NOTE
Mounting hardware is supplied with ECU.
6.
Mount ECU (Figure 10, Item 1) to fold-down panel (Figure 10, Item 2).
7.
Remove four ring bolts from ECU transport location and store in shelter BII box (WP 0002 00, Figure 2, Item
5 or Figure 3, Item 6).
8.
Remove four setscrews (WP 0068 00, Figure 2, Item 18 or 19) from shelter BII box (WP 0002 00, Figure 2,
Item 5 or Figure 3, Item 6) and install into empty loor inserts (WP 0047 00, Figure 2).
CONNECTING POWER TO ECUS
NOTE
There are several ECU conigurations compatible for this shop set. Refer to your shop s
Applicable ECU Owner s Manual for operating, grounding, and maintenance instructions.
Figure 11.
Connecting Power to ECUs.
1.
Inspect installation of ECU (A) (Figure 11, Item 1) and power cable (Figure 11, Item 3).
2.
Position MODE switch (Figure 11, Item 2) to OFF position.
3.
Remove protective dust cap (Figure 11, Item 7) from power input receptacle (Figure 11, Item 6).
4.
Push end of connector (Figure 11, Item 5) into power input receptacle (Figure 11, Item 6) until seated.
5.
Screw connector lock ring (Figure 11, Item 4) on power input receptacle (Figure 11, Item 6).