Figure 3. Loops and Clamps Installation.
OPERATION FOR IMPROVING SOIL CONDUCTIVITY FOR SHELTER GROUNDING

Maintenance Manual For Production/ Quality Control Shop Part No. 1036659 And Part No. Sc4920-99-Cla66
Page Navigation
  132    133    134    135    136  137  138    139    140    141    142  
img
.
TM 1-4920-440-13&P
0035 00
UNUSUAL ENVIRONMENT/WEATHER CONTINUED
OPERATION IN HIGH WINDS CONTINUED
NOTE
A minimum of a quarter turn is required to remove maximum holding power.
Figure 4.
Securing Loops and Clamps.
5.
Insert driving rod through loop and pull up sharply to ensure anchor is set into ground.
NOTE
When moving shelter, disassemble storm coniguration kit and cut cable as close to ground as
possible. Discard cable components. Retain the two tie-down rings and store in shelter Basic
Issue Items (BII) box (WP 0002 00, Figure 2, Item 5 or Figure 3, Item 6)
Figure 5.
Attaching Loops and Clamps.
6.
Remove clamp, loop cable at six places (two with tie-down rings) as shown.
7.
Replace clamp and tighten clamp nuts.
0035 00-5