TM 1-4920-450-13&P
3-15. Fixtures - Water Feed Thru Connector- Replace
3-15
This tasks covers: Replacement of connector
INITIAL SETUP
Tools:
Basic Issue Items (BII) - App C
Material:
Feed thru connector - App F
Adhesive, NSN 8040-00-877-9872- App E
Personnel Required:
44E Machinist and Helper
Faucet and adapters removed
REPLACE CONNECTOR
1. Remove six screws (1), lockwashers (2), washers (3)
and nuts (4) securing connector (5).
2. Remove connector (5) from panel and scrape off old
adhesive.
GO TO NEXT PAGE
3-17