TM 1-4920-452-13&P
Perform the following steps only when shrinking/stretching machine
is to be used. Removal of retainer bar releases foot pedal. When
released, pedal extends out in front of machine and into doorway of
personnel entrance.
This extended pedal could result in injury to
personnel running into or tripping over pedal. When not in use
retainer bar which secures pedal in storage position will be installed.
j. Preparing Shrinking/Stretching Machine for
Operation. Remove nut (1) and washer (2) from stop
bar (3) inserted through shrinking/stretching machine
base (4). Remove bar (3).
2-21