TM 1-4920-500-13&P
0036 00
1
SSAE175
6. Install new air feed-thru connector assembly (1) from outside of shelter with long end through hole.
2
3
4
5
2
9
1
1
SSAE176
7. Install all but one screw (2), have assistant install flat washers (3), lock washer (4), and nuts (5) inside of
shelter and secure.
8. Replace one lanyard (9) on outside of shelter and install screw (2).
9. Have assistant install flat washer (3), lock washer (4), second lanyard (9), and nut (5) on inside of shelter.
10. Tighten screws (2).
End of Work Package
0036 00-7/(0036 00-8 blank)