TM 10-5411-236-13&P
0005 00
WARNING
Make sure all container connectors are properly seated and secured. Failure to comply
could cause serious injury, death, or property damage.
9.
Insert the long end of the loading rail connectors into the open ends of the loading rails on the FPU
12. Fully insert until they are firmly seated with the load rail blocks contacting the ends of the loading
rails and just under the edge of the FPU-12 container.
-INCH HEX BOLT
TRANSVERSAL
-INCH HEAVY LOCK
STABILIZER
WASHER
-INCH HEAVY FLAT
FPU-12
WASHER
FPU-8
TENSIONING
BLOCKS
HORIZONTAL
LOAD RAIL
INTERCONNECTOR
BLOCKS
CAUTION
Check loading rail assembly connection areas to be sure they are free of debris before
mating assembly pieces.
10. Install the transversal stabilizer crossbar onto the load rail connectors. Using the 1 1/8-inch socket,
-inch drive flex head wrench and 2-inch long extension tighten the -inch bolts (with flat washer
closest to stabilizer and lock washer above insert the -inch bolts and tighten firmly).
11. Ensure the two expandable end-tensioning blocks are fully retracted by adjusting tensioning block
bolts and jam nuts.
0005 00-11