TM 5-4310-381-13
2-6.
STOPPING ENGINE.
a. Remove all compressor load from engine.
b. Move throttle control to idle position, allow engine to cool for approximately 2 minutes.
c. Turn ignition switch off or press the stop button.
d. Close the fuel shut off valve.
2-7. CONTROLS AND INSTRUMENTS.
a. Refer to the engine illustration for location, purpose and normal setting of 2A016-I engine.
b. Refer to the engine illustration (paragraph 2-5) for location, purpose and normal setting of engine controls that are
applicable to the Models 2A016-II and 2A016-III engines.
2-8.
COMPRESSOR OPERATING PROCEDURE.
Operating Compressor
a. Perform all the B (Before Operation) PMCS listed in Table 2-1.
b. Remove hoses (1) from frame and couple to quick connect fittings (2) on pump outlet tee.
c. Store rubber cords (3) securing hoses in tool box (4).
d. Install inflator valve assemblies (5) on end of hoses.
e. Refer to paragraph 2-5 for starting engine.
f.
After engine warm-up, couple inflator valves to quick connect fittings on equipment being serviced.
2-10