POSITIONING ECUS FOR TRANSPORT MODE
Figure 3. Secure ECU (B).

Operator Manual \(Rpstl\) For Pneudraulic Shop P/N Sc4920-99-Clc64 And Part No 1036258
Page Navigation
  74    75    76    77    78  79  80    81    82    83    84  
img
0020 00
TM 1-4920-433-13&P
DISCONNECTING POWER FROM ECUS - CONTINUED
1.
Set MODE switch (Figure 1, Item 2) on ECU (B) (Figure 1, Item 1) to OFF position.
2.
Unscrew connector lock ring (Figure 1, Item 4) from power input receptacle (Figure 1, Item 6).
3.
Pull end of connector (Figure 1, Item 5) from power input receptacle (Figure 1, Item 6).
4.
Store power cable (Figure 1, Item 3) in secure storage location.
5.
Install protective dust cap (Figure 1, Item 7) on power input receptacle (Figure 1, Item 6).
6.
Repeat Steps 1 through 5 for ECU (A).
POSITIONING ECU (B) FOR TRANSPORT MODE
1.
Remove three setscrews from ECU (B) transport location loor inserts and store in cotton mailing bag located
in shelter BII box.
2.
Remove two cargo straps (Figure 3, Item 3) from secure storage location and three ring bolts (Figure 3, Item
4) from shelter BII box.
3.
Install three ring bolts (Figure 3, Item 4) into loor inserts at transport location.
Figure 2.
Removing ECU (B) Hardware from ECU Fold-down Panel.
4.
Remove mounting hardware (Figure 2, Item 2) securing ECU (B) (Figure 2, Item 1) to ECU fold-down panel
(Figure 2, Item 3).
5.
Store hardware in cotton mailing bag located in shelter BII box .