CHECKING SHELTER LEVEL
Figure 2. Replacing Protective Dust Cap.

Operator Manual \(Rpstl\) For Pneudraulic Shop P/N Sc4920-99-Clc64 And Part No 1036258
Page Navigation
  71    72    73    74    75  76  77    78    79    80    81  
img
. .
TM 1-4920-433-13&P
0019 00
OPERATOR INSTRUCTIONS
PNEUDRAULIC SHOP
DISCONNECTING COMPRESSED AIR AND WATER
INITIAL SETUP:
Personnel Required
Tools and Special Tools
General Mechanics Tool Kit
CMF 15 Series (1)
(WP 0062 00, Table 2, Item 104 )
Equipment Condition
Functional
DISCONNECTING COMPRESSED AIR
WARNING
Ensure air pressure has been relieved before disconnecting compressed air supply. Do not
direct compressed air near eyes or directly against skin. Wear eye protection; high pressure air
against eyes can cause BLINDNESS.
Figure 1.
Disconnecting Compressed Air.
1.
Remove quick disconnect coupling (Figure 1, Item 2) from air feed-thru connector assembly (Figure 1, Item
3) located on services utility panel (Figure 1, Item 1) and store in secure storage location.
0019 00-1