• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
MAINTENANCE INSTRUCTIONS FOR FIRST AID BRACKET ASSEMBLY AND HARDWARE - Continued
Figure 1. Testing ECU Power Cable.

Operator Manual \(Rpstl\) For Pneudraulic Shop P/N Sc4920-99-Clc64 And Part No 1036258
Page Navigation
  179    180    181    182    183  184  185    186    187    188    189  
img
. . . . . .
TM 1-4920-433-13&P
0049 00
FIELD MAINTENANCE
PNEUDRAULIC SHOP
MAINTENANCE INSTRUCTIONS FOR ECU POWER CABLE ASSEMBLY
INITIAL SETUP:
Materials/Parts
Tools and Special Tools
Tape, Electrical Scotch Super 33 plus 1 inch
Electrical Repairers Tool Kit
(WP 0069 00, Item 9)
(WP 0062 00, Table 2, Item 103 )
Twine, Fibrous (WP 0069 00, Item 10)
General Mechanics Tool Kit
(WP 0062 00, Table 2, Item 104 )
Personnel Required
Multimeter (WP 0062 00, Table 2, Item 106 )
CMF 15 Series (1)
Equipment Condition
Functional
WARNING
HIGH VOLTAGE exists in electrical system of shop. All electrical inspections, repairs, or
replacements will be performed with power OFF and only by a qualiied electrician. Serious
shock hazards exist which could result in INJURY OR EVEN DEATH to personnel.
NOTE
During installation of components same hardware should be used so as to maintain
original integrity of shop set.
If ECU NSN 4120-01-523-4472 is being used, it may be necessary to change existing
electrical plug connector on end of ECU cables to electrical plug connector (NSN 5935-
01-413-4953) to ensure ECU power cable is compatible with ECU.
INSPECTION OF INSTALLED ITEMS
ECU POWER CABLE
Inspect ECU power cable connectors and ECU power cable for any type of damage.
0049 00-1


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.