CHECKING SHELTER LEVEL
Figure 2. Replacing Protective Dust Cap.

Field Maintenance Manual For Sheet Metal Shop Part No. 1035658 And Part No. Sc4920-99-A68
Page Navigation
  83    84    85    86    87  88  89    90    91    92    93  
img
. .
TM 1-4920-435-13&P
0022 00
OPERATOR INSTRUCTIONS
SHEET METAL SHOP
DISCONNECTING COMPRESSED AIR AND WATER
INITIAL SETUP:
Personnel Required
Tools and Special Tools
General Mechanics Tool Kit
CMF 15 Series (1)
(WP 0072 00, Table 2, Item 104 )
Equipment Condition
Functional
DISCONNECTING COMPRESSED AIR
WARNING
Ensure air pressure has been relieved before disconnecting compressed air supply. Do not
direct compressed air near eyes or directly against skin. Wear eye protection; high pressure air
against eyes can cause BLINDNESS.
Figure 1.
Disconnecting Compressed Air.
1.
Remove quick disconnect coupling (Figure 1, Item 2) from air feed-thru connector assembly (Figure 1, Item
3) located on services utility panel (Figure 1, Item 1) and store in secure storage location.
0022 00-1