MAINTENANCE INSTRUCTIONS FOR WATER AND AIR FEED-THRU CONNECTOR ASSEMBLIES
Figure 4. Water Feed-thru Connector Flange.

Field Maintenance Manual For Sheet Metal Shop Part No. 1035658 And Part No. Sc4920-99-A68
Page Navigation
  239    240    241    242    243  244  245    246    247    248    249  
img
0062 00
TM 1-4920-435-13&P
REMOVAL
WATER FEED-THRU CONNECTOR ASSEMBLY
Figure 2.
Disassembly of Water Feed-thru Connector Assembly.
1.
Have assistant hold nut (Figure 2, Item 5) and washer (Figure 2, Item 3) inside shelter.
2.
Remove nuts (Figure 2, Item 5), lat washers (Figure 2, Item 3), lock washers (Figure 2, Item 4), and screws
(Figure 2, Item 2), releasing water feed-thru connector assembly (Figure 2, Item 1).
Figure 3.
Removal of Water Feedthru Connector Assembly.
3.
Remove water feed-thru connector assembly (Figure 3, Item 2) from services utility panel.
4.
Remove old caulking compound (Figure 3, Item 1).