  238    239    240    241    242  243  244    245    246    247    248  
img
. . .
TM 1-4920-435-13&P
0062 00
FIELD MAINTENANCE
SHEET METAL SHOP
MAINTENANCE INSTRUCTIONS FOR WATER AND AIR FEED-THRU CONNECTOR ASSEMBLIES
INITIAL SETUP:
Personnel Required
Tools and Special Tools
CMF 15 Series (2)
General Mechanics Tool Kit
(WP 0072 00, Table 2, Item 104 )
Equipment Condition
Materials/Parts
Functional
Compound, Caulking (WP 0078 00, Item 1)
INSPECTION OF INSTALLED ITEMS
WATER FEED-THRU CONNECTOR ASSEMBLY
Figure 1.
Inspect Water Feed-Thru Connector Assembly.
1.
Inspect condition of threads on both ends of water feed-thru connector (Figure 1, Item 2).
2.
Replace if damage is detected.
3.
Ensure that protective dust caps (Figure 1, Item 1) are attached.
4.
Ensure that weld on connector is not cracked or broken. If defective, replace.