CONNECTING COMPRESSED AIR AND WATER
CHECKING SHELTER LEVEL

Maintenance Manual For Engine Shop Part No. 1035258 And Part No. Sc4920-99-Cla60
Page Navigation
  68    69    70    71    72  73  74    75    76    77    78  
img
0016 00
TM 1-4920-436-13&P
CONNECTING COMPRESSED AIR - CONTINUED
Figure 2.
Connecting Compressed Air.
2.
Remove a quick disconnect coupling (Figure 2, Item 2) from storage location.
3.
Install the quick disconnect coupling (Figure 2, Item 2) on air feed-thru connector assembly (Figure 2, Item 3)
at services utility panel (Figure 2, Item 1) and tighten securely.
CONNECTING WATER SUPPLY
Figure 3.
Connecting Water Supply.
1.
Remove protective dust caps (Figure 3, Item 2) from each end of water feed-thru connector assembly (Figure
3, Item 3) at services utility panel (Figure 3, Item 1).
2.
Remove a quick disconnect coupling from storage location.
3.
Install adapters and ittings as required and tighten securely.
END OF WORK PACKAGE