Figure 2. Key Cabinet (SC4920-99-CLA66).
MAINTENANCE INSTRUCTIONS FOR EYEWASH STATION ASSEMBLY BRACKET AND HARDWARE

Maintenance Manual For Production/ Quality Control Shop Part No. 1036659 And Part No. Sc4920-99-Cla66
Page Navigation
  166    167    168    169    170  171  172    173    174    175    176  
img
TM 1-4920-440-13&P
0045 00
INSPECTION OF INSTALLED ITEMS CONTINUED
KEY CABINET (SC4920-99-CLA66) CONTINUED
1.
Inspect key cabinet (Figure 2) for damage. Replace as necessary.
2.
Inspect all key cabinet hardware (Figure 2, Item 2, 3, and 4) for rust, cracks and rounded heads. Replace as
necessary.
REMOVAL
Remove two bolts (Figure 2, Item 4), two lock washers (Figure 2, Item 3), two lat washers (Figure 2, Item 2) and
key cabinet (Figure 2, Item 1).
INSTALLATION
1.
Position key cabinet (Figure 2, Item 1) by aligning bolt holes with wall inserts.
2.
Install two bolts (Figure 2, Item 4), two lock washers (Figure 2, Item 3), and two lat washers (Figure 2, Item
2), attaching key cabinet (Figure 2, Item 1) to shelter wall.
Torque bolts (Figure 2, Item 4) 160-190 in. lbs.
3.
END OF WORK PACKAGE