• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
CHECKING SHELTER LEVEL
Figure 2. Replacing Protective Dust Cap.

Operator Manual For Tool Crib Shop Part No. 1036058 & Part No. Sc4920-99-Cla69
Page Navigation
  75    76    77    78    79  80  81    82    83    84    85  
img
. .
TM 1-4920-441-13&P
0020 00
OPERATOR INSTRUCTIONS
TOOL CRIB SHOP
DISCONNECTING COMPRESSED AIR AND WATER
INITIAL SETUP:
Personnel Required
Tools and Special Tools
General Mechanics Tool Kit
CMF 15 Series (1)
(WP 0059 00, Table 2, Item 104 )
Equipment Condition
Functional
DISCONNECTING COMPRESSED AIR
WARNING
Ensure air pressure has been relieved before disconnecting compressed air supply. Do not
direct compressed air near eyes or directly against skin. Wear eye protection; high pressure air
against eyes can cause BLINDNESS.
Figure 1.
Disconnecting Compressed Air.
1.
Remove quick disconnect coupling (Figure 1, Item 2) from air feed-thru connector assembly (Figure 1, Item
3) located on services utility panel (Figure 1, Item 1) and store in secure storage location.
0020 00-1


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.