• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS)
Table 1. PREVENTIVE MAINTENANCE CHECKS AND SERVICES (PMCS) - Continued

Maintenance Manual For Aviation Shop Equipment Contact Maintenance System
Page Navigation
  19    20    21    22    23  24  25    26    27    28    29  
img
. . . .
0010
TM 1-4920-924-13&P
AVIATION SHOP EQUIPMENT CONTACT MAINTENANCE (AV SECM) SYSTEM PREVENTIVE MAINTENANCE
CHECKS AND SERVICES (PMCS) - (CONTINUED)
EQUIPMENT
ITEM TO BE
ITEM
INTERVAL
NOT READY/
CHECKED OR
NO.
PROCEDURE
AVAILABLE IF:
SERVICED
Ensure curbside rack assembly tie down
17
During
Tie down
Curbside Rack
assemblies are not damaged due to dry rot or  assemblies
Assembly
broken fastener components. Ensure tie down cannot properly
Tie Down
assembly webbing material is not frayed, torn  secure mission
Assemblies
or broken (WP 0015).
essential
equipment.
18
During
Curbside Rack
Ensure all tool cases being stowed (WP 0002)
Assembly
on the curbside rack assembly are properly
Stowed Tool
secured to the curbside rack assembly using
Cases
tie down assemblies.
Tie down
Ensure workbench assembly tie down
19
During
Workbench
assemblies are not damaged due to dry rot or  assemblies
Assembly
broken fastener components. Ensure tie down cannot properly
Tie Down
assembly webbing material is not frayed, torn  secure mission
Assemblies
essential
or broken (WP 0015).
equipment.
20
During
Workbench
Ensure all tool cases being stowed (WP 0002)
Assembly
on the workbench assembly are properly
Stowed Tool
secured to the workbench assembly using tie
Cases
down assemblies.
21
During
LED Flexible
Ensure LED lexible table lamp is operational.
Table Lamp
Power inverter is
22
During
Power Inverter
Ensure power inverter is operational.
nonoperational.
(Airpax Dimensions, Inc. DC to AC power
Inverters Owners Manual for Models: MIL-
24/6000H-3PHQ).
23
During
Oil-free air
Oil-Free Air
Check oil-free air compressor for proper
compressor is
Compressor
operation (Instruction manual Oil-Free
nonoperational.
Portable Air Compressor).
Ensure proper quick disconnect ittings are
Improper quick
installed on oil-free air compressor that are
disconnect ittings
compatible with equipment being used with
are installed
the AV SECM assembly.
on oil-free air
compressor.
Remote area
Ensure Remote Area Lighting Assembly
24
During
Remote
lighting assembly
is operational. (Instruction Manual, 9450B
Area Lighting
is nonoperational.
Remote Area Lighting System Owner s
Assembly
Manual).
Remote area
Ensure Remote Area Lighting Assembly
lighting assembly
batteries have suficient charge (Instruction
batteries do not
Manual, 9450B Remote Area Lighting System have suficient
Owner s Manual).
charge.
25
Fire
Fire extinguisher
After
Ensure ire extinguisher is present and
Extinguisher
is not present or
serviceable.
not serviceable.
00103


Privacy Statement
Press Release
Contact

© Copyright Integrated Publishing, Inc.. All Rights Reserved.