0016
TM 1-4920-924-13&P
AVIATION SHOP EQUIPMENT CONTACT MAINTENANCE (AV SECM) SYSTEM MAINTENANCE
INSTRUCTIONS FOR POWER INVERTER - (CONTINUED)
21
1
22
SECM0085A
Figure 4.
14. On right hand side of power inverter (Figure 4, Item 1) loosen ground lug (Figure 4, Item 21) and remove
ground wire (Figure 4, Item 22).
15. Remove six 3/8-24 X 0.75 hex head bolts (Figure 1, Item 2), twelve 3/8 inch lat washers (Figure 1, Item
3), six 3/8 inch lock washers (Figure 1, Item 4) and six 3/8-24 inch hex nuts (Figure 1, Item 5) from power
inverter (Figure 1, Item 1) and remove power inverter (Figure 1, Item 1) from SECM workbench assembly.
END OF TASK