TM 5-3610-256-14
5-9. REPAIR TANK.
TOOLS: Safety Goggles
Flat-Tipped Screwdriver
Cross-Tipped Screwdriver
SUPPLIES: Developer Screen
Polyester Pick-off(s)
End Gaskets
Grommets
Sealant
Double-Sided Tape
Unplug power cord before servicing machine. Death
or injury may result from failure to comply with this
warning.
Ammonia vapor may cause injury or death. Do not breathe vapor.
Ensure adequate ventilation before servicing or operating
machine.
Ammonia may cause eye injury or blindness. Wear eye protection
before servicing ammonia system.
Ammonia may cause skin burns or irritation. Do not let ammonia
contact skin or clothing.
First Aid: If ammonia is spilled on skin, promptly wash with plenty
of water. Remove clothing if necessary to wash off affected area.
If eyes are affected, rinse with fresh water as soon as possible.
Continue for at least 15 minutes. Anyone overcome by ammonia should
be removed to fresh air at once. Refer to FM21-11 and apply artificial
respiration. Use oxygen if breathing is labored or has stopped.
Obtain medical attention at once in cases of eye contact, burns to
nose or throat, or if person is unconscious.
a. Power OFF.
b. Unplug power cord.
c. Remove developer pick-off assembly. Remove rear cover.
5-10