TM 5-3610-256-14
Table 4-3. Direct Support Troubleshooting (Continued)
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
3.
POOR DEVELOPMENT (CONTINUED).
Step 3. Test heater rod for continuity.
Replace defective heater rod (see paragraph 4-17).
Step 4. Test time delay.
Adjust or replace time delay (see paragraph 4-19).
Refer to next higher level of maintenance.
4.
EXCESSIVE AMMONIA ODOR.
Step 1. Inspect for condensation in pump and lines.
Remove condensation (see paragraph 4-13).
Step 2. Check vacuum chamber for condensation.
Remove condensation (see paragraph 4-13).
Step 3. Inspect developer tank.
Replace defective developer tank (see paragraph 4-20).
5.
PRINTS WRINKLED OR SMUDGED.
Step 1. Inspect tension studs and belt setting.
Adjust belt tension (see paragraph 4-18).
Step 2. Test drive motor.
Adjust or repair drive motor as required (see paragraph 4-21).
Step 3. Defective chain.
Replace drive chain as required (see paragraph 4-20).
Step 4. Defective cylinder.
Replace cylinder (see paragraph 4-22).
4-8
Change 1