4-22
TM 5-3610-256-14
g. Remove developer roller drive sprocket by loosening socket head setscrew (1) and pulling
sprocket (2) from shaft.
Ammonia vapor may cause injury or death. Do not breathe vapor.
Ensure adequate ventilation before servicing or operating
machine.
Ammonia may cause eye injury or blindness. Wear eye protection
before servicing ammonia system.
Ammonia may cause skin burns or
irritation. Do not let ammonia contact skin or clothing..
h. Disconnect tubing (3) from developer tank.
Remove developer tank assembly.
i. Disconnect heater wires (4) from developer tank.