TM 5-3610-256-14
a. Remove right cover by turning captive screw.
b. Plug in power cord.
c. Power ON.
d. Process one print and determine the amount of time the machine takes to shut off after
processing. Factory setting is 2-1/2 minutes.
e. Adjust potentiometer (1) turning knob. Turning to right increases time delay (maximum
5 minutes). Turning to left decreases time delay.
f. Power OFF.
g. Unplug power cord.
h. Reinstall right cover and turn captive screw.
4-25