TM 5-4310-381-13
TABLE 2-1. Operators Preventive Maintenance Checks and Services (Continued)
B - Before Operation D - During Operation A - After Operation W - Weekly
3
AIR FILTER ASSEMBLY
Filter blocked. '~
a. Unscrew the wing nut (1) and remove the upper
housing (2).
WARNING
Drycleaning solvent, P-D-680, used to clean
parts is potentially dangerous to personnel
and property. Avoid repeated and prolonged
skin contact by wearing rubber or non-porous
gloves when handling the solvent or material
wet with drycleaning solvent. Wash hands
immediately after exposure with soap and
water and use a lanolin based skin cream to
prevent skin drying. Do not use near open
flame or excessive heat. Flash point of solvent
is 1 000F (380C). Do not work with solvent
in a closed room. Be sure there is good
ventilation or the solvent vapors will build up
in the air and become a poisonous mixture
which can cause physical injury or even death.
b. Clean the foam sleeve (3) with P-D-680.
c. Inspect the filter element (4) for dirt collection.
ITEM
NO.
INTERVAL
ITEM TO BE INSPECTED. PROCEDURE:
EQUIPMENT NOT
READY/AVAILABLE IF:
B D A W
2-4