TM 55-4920-217--15
o. Insulated Side Panels. The shop is equipped
with insulated side panels to insure weather proof and air
tight seals around side-walls when folding sides are
opened. Six panels are provided for each side (4
straight panels and 2 corner panels), and are stored, 1
set of 6, in each of the chests (fig. 22), when not in use
or in transit. A special wrench is provided to install or
detach the panels. Installation or detachment can be
accomplished by 2 men in a few minutes. Figure 29
illustrates the installation of the panels.
p. Ventilation. The shop is provided with adequate
ventilation facilities for normal operating conditions.
Ducts, vents, and ventilating equipment should be
checked periodically for cracks, dents, obstructions, and
functioning of equipment. When the equipment is
operated in extreme hot weather, ventilation, equipment
should be inspected as often as practical to insure
MTG. PL. 1/4 THK. STL. PL.
proper operation of the equipment and the operator's
comfort. Details of ventilation facilities are shown in TM
9-2330-238-14.
m. Bench Tops. Bench tops are mounted on the
q. Air Conditioning. An air conditioner unit is
top of the storage cabinets. Lag screws are installed to
installed by the manufacturer at the approximate location
mount the bench tops as shown in figure 71. Additional
shown in figure 22. The operating instructions and
security of the bench tops is obtained when bench
switches are with the unit. Manufacturer's literature
mounted equipment is installed as the mounting bolts for
should be used for operation and maintenance.
the equipment pass through the bench top and the top of
n. Cabinet, Storage. Storage cabinets are floor
mounted and bolted together when adjacent. Typical
78