TM 55-4920-402-13&P
Para/Step
4-13c (3)
4-13c (6), (7)
4-13d (3),
e(5), f(5),
g(4). (6),
(9), (11)
4-14a
4-14b
4-14g
4-14h
Table 4-18. Troubleshooting Procedures (Strobex/Tester)
Trouble
mproper Voltages
Table 4-8
mproper Voltage at TP6
mproper Indications
mproper Indications at
TP9, TP10, Rear Terminal
C1201; Junction of
CR1203 and L 1202
Probable Cause
Defective Components
Fuse F1 blown
High Voltage Power Supply
Defective
Oscillator Defective
Oscillator Defective or
Misadjusted
Tester-Section
Perform 4-14a to Determine Operational Capability of Tester
Motor does not run
Grinding Noise
Profile cam out of tolerance
Rotor Disc hits Magnetic
Pickup
Probable Remedy
Associated components
(Fig C-5) and Perform
Para 4-13 as required
or Para/Step below
1.
F1 Fuse (Fig 4-
11)
2.
Q1, Q2, Q6 (Fig
4-11) A501, S501
(24, 11, Fig C-5)
and associated
components (Fig
FO-3)
Q4 (Fig 4-11), A501
(24, Fig C-5) and
associated com-
ponents (Fig FO-3)
Q3, Q5 (Fig 4-11),
S501B (11 Fig C-5)
and associated com-
ponents (Fig F03). Ad-
just Strobex (Para 4-
20c)as necessary.
Blown Fuse or Defective
Motor
F101 Fuse (39 Fig C-
7),
Motor B1 (28 Fig
C-7) or associated
components (Fig C-7).
Cam follower rubs against
Adjust set screw (11
profile cam
Fig C-7).
Worn profile cam
1.
Replace profile
cam (12, Fig C-7).
Rotor hub screws rubs
2.
Loosen set screw
against motor
(11, Fig C-7) and
adjust height of
rotor hub and
rotor disc as re-
quired.
Rotor disc improperly set
Same as above 4-14g
(2).
Change 4
4-16.5