TM 55-4920-402-13&P
NOTE
Soldering Techniques. Use a stiff, non-
metallic bristle brush to clean anti-
fungus material away from area to be
unsoldered and soldering iron between
25 and 40 watts (600 to 900 degrees F).
Do not exceed 40 watts. Use resolder-
ing equipment, such as a solder sucker,
while unsoldering parts and heat sinks
on transistor or diode leads when
soldering or unsoldering. Use solder
per Federal Specification QQ-S-571D.
Apply anti-fungus material (MIL-STD-
1250) after completion of repairs.
NOTE
Circuit Card Repair. Special soldering
equipment is needed for solid state
components; i.e., microcircuits,
transducers and semiconductors that
can be easily damaged by excessive
heat. Repairs to the Balancer circuit
cards are made with the cards in place.
The Strobex circuit card may be
removed for repair. The following in-
structions, and those in the preceding
paragraph, are applicable to the
Balancer circuit cards and the Strobex
circuit card.
4-20. Adjustment Procedures. Perform these
procedures only when directed by the
troubleshooting procedure (Table 4-17), or
paragraph 4-11d (16).
a, Balancer Adjustments. Perform these pro-
cedures only when directed by the
troubleshooting procedures (Table 4-17), or
paragraph 4-11d (16).
(1) Connect Balancer and test equipment as
shown in Figure 4-6.
(2) Set Balancer FUNCTION switch to
TRACK, R.P.M. RANGE switch to X10, and
R.P.M. TUNE dial to 100.
(3) Remove cover by removing 4 screws.
(4) Connect VOM between TP2 and ground,
and adjust R152 for a 0 ± 3 mV indication.
(5) Connect VOM between TP3 (Fig. 4-5)
and ground, and adjust R152 for a 0 ± 3 mV in-
dication.
4-16
Change 4
(6) Set FUNCTION switch to B and R.P.M.
TUNE dial to past 999 to 000.
(7) Set up function generator for a sine wave
output of 166.67 Hz at 115 mV rms.
(8) Connect oscilloscope horizontal input to
TP8 and vertical input to TP2.
(9) Press and hold VERIFY TUNE switch
and adjusat R114 for a 90° phase shift display
(circle). Release switch.
(10) Connect oscilloscope vertical input to
TP3.
(11) Press and hold VERIFY TUNE switch
and adjust 135 for a 90° phase shift display (cir-
cle). Release switch. Repeat steps (9) thru (11) for
optimum adjustment.
(12) Adjust R155 until IPS meter indicates
full scale.
(13) Set R.P.M. TUNE dial to 100.
(14) Set up function generator for a 16.67
Hz sine wave output at 11.5 mV rms.
(15) Connect oscilloscope horizontal input
to TP8 and vertical input to TP2.
(16) Press and hold VERIFY TUNE switch
and adjust R126 for a 90° phase shift display
(circles). Release switch.
(17) Connect oscilloscope vertical input to
TP3.
(18) Press and hold VERIFY TUNE
switch and adjust R148 for a 90° phase shift
display (circles), Release switch. Repeat steps
(16) thru (18) for optimum adjustment.
(19) Position
Balancer and function
generator controls as indicated in Table 4-16.
Observe readings as in dicated in Table 4-16 (See
note below Table.)
(20) Disconnect equipment and replace
cover.
b. Phazor Adjustments. Perform these pro-
cedures only when directed by the
troubleshooting procedures (Table 4-17).
(1) Connect Balancer and test equipment as
shown in Figure 4-8.
(2) Set FUNCTION switch to A, R.P.M.
RANGE switch to X10, and INTERRUPTER
LOGIC switch to SINGLE.