TM 55-4920-402-13&P
CHAPTER 2
OPERATING INSTRUCTIONS
2-1. General. This chapter provides complete operating
2-2 Controls and lndicators. Figure 2-l and table 2-l
instructions for the VIBREX. Included are illustrations
illustrates and describes the controls and indicators for
and fictional descriptions of all controls and indicators,
the Balancer, figure 2-2 and table 2-2 illustrates and des-
operating procedures, and the use of balance and tracking
charts. Troubleshooting techniques for the isolation of
tribes the controls and indicators for the Strobex, and
figure 2-3 and table 2-3 illustrates and describes the con-
malfunctions, other than tracking and balancing rotor
blades, are also discussed.
trols and indicators for the Tester
CAUTION
Extreme care should be exercised when
ponents and assemblies which may be
using the VIBREX test set. This unit
easily damaged if subjected to physical
contains delicate electronic com-
abuse due to improper handling.
Table 2-1. Balancer Controls and Indicators
Figure &
Index No.
Control/Indicator
Function
2-1-1
FUNCTION 3-position switch
CHANNEL A accelerometer typically used to
measure lateral one-per-revolution for main
rotor balance. CHANNEL B accelerometer
typically used to measure vertical one-per-
revolution for main rotor track adjustment.
Also used for tail rotor balancing.
TRACK connects Magnetic Pickup signal to
trigger Strobex.
2-1-2
IPS meter
Reads vibration amplitude in IPS. Scale no.
1 reads 0 to 1.0 IPS. Scale no. 2 reads 0 to
10.0 IPS.
2-1-3
PUSH FOR SCALE 2 pushbutton
Divides IPS meter reading by 10. IPS meter
reads 0 to 10.0 IPS.
2-1-4
RPM TUNE dial
Tunes band-pass filters to the exact rotor RPM.
2-1-5
VERIFY TUNE pushbutton
Switches the filter from normal to sharp peak
con figuration.
2-1-6
PHAZOR ring-of-lights
A phase meter that measures the phase, or
clock angle, between the rotor azimuth angle
derived from the Magnetic Pickup inputs and
the Accelerometer. Also serves as power indi-
cator light.
2-1-7
TEST pushbutton
Disconnects the Accelerometer inputs and
applies the Magnetic Pickup inputs to Phazor.
2-1-8
INTERRUPTER LOGIC switch
The SINGLE position is used when only one
Interrupter is installed. The DOUBLE position
is used if the swashplate has one Interrupter
per blade, one of which is double to provide
the one-per-revolution azimuth reference.
2-1-9
RPM RANGE 3-position switch
Xl range is 999 RPM range maximum, X10
range is 9,990 RPM range maximum, and X100
is 99, 900 RPM range maximum.
2-1-10
MAGNETIC PICKUP switch
COMMON connects the two Magnetic Pickup
inputs together so that both Accelerometer
inputs are referenced to the same Magnetic
Pickup pulse from the fixed swashplate. The
INDEPENDENT position is used only if two
Magnetic Pickups are used, as on the left and
right propellers of an airplane.