13-19. SWITCHBOX AND MOUNTING BRACKET (WITHOUT TOGGLE SWITCH)--MAINTENANCE INSTRUCTIONS(cont)
REASSEMBLY/INSTALLATION (cont)
15 TWO HEX HEAD CAPSCREWS (24).
Install in mounting bracket (1) and switchbox
(8).
14 COVER (22).
a. Install on switchbox (8) .
b. Install four screws (23).
ADJUSTMENT OF MICROSWITCH
TEST
NOTE
Adjusting two hex nuts inward moves
plunger forward, adjusting outward
moves plunger backwards.
1
PERSONNEL DOOR AND CARGO
DOOR.
PLUNGER (1) OF MICROSWITCH (2) .
Close.
Adjust two hex nuts (3).
3-186