TM 9-4933-223-13&P
3-31. WIRE ASSEMBLY (CEILING OUTLETS)--MAINTENANCE INSTRUCTIONS
This task covers:
a. Removal
d.
Repair
b. Inspection
e.
Reassembly
c. Disassembly
f.
Installation
INITIAL SETUP:
Special Tools
General Safety Instructions
Armament repair shop set (SC 4933-95-CL-A21)
Basic aircraft armament repair tool set
WARNING
(SC 5180-95-CL-B09)
The shop set contains voltages which are
Supplemental aircraft armament repair tool set
dangerous if contacted. Before perform-
(SC 5180-95-CL-B10)
ing any maintenance on the wire assembly,
be sure the circuit breaker on power
Material s/Parts
distribution panel connected to the power
Abrasive cloth (item 4, app D)
source is in the OFF position and the
Lug terminal (MS25036-156)
120/208V cable assembly is disconnected
Wire (12011690-9)
from the shelter.
References
NOTE
There are four wire assemblies tagged no.
11A, no. 11B, no. 14A, and no. 14B used
in the J20, J21, and J22 conduit boxes
Wire table.
and J23 receptacle box to ground the
Disassembly and reassembly procedures for
electrical receptacle. Each assembly
shop set--electrical installation.
consists of one 4.00-in. (10.16-cm) green
wire with a lug terminal attached to one
following procedures are written for a
quantity of one wire assembly and must be
repeated for the other wire assemblies.
Change 1 3-248